Olympus Extends Portfolio for EBUS-TBNA at ATS

ViziShot 2 EBUS-TBNA Needles Provide Improved Flexibility, Increased Sharpness and an Ergonomic Handle to Help Optimize Access, Usability and Puncture of Difficult-to-Reach Lymph Node Targets

Side by side Vizishot trademark 2 needles identified as 21 G and 22 G EBUS-TBNA needles above Olympus logo and Vizishot trademark 2 flex needle below identified as 19 EBUS-TBNA needle

Olympus announces new ViziShot 2 single-use aspiration needles, expanding the device portfolio for Endobronchial Ultrasound Transbronchial Needle Aspiration (EBUS-TBNA), a minimally invasive alternative to a surgical procedure and considered the gold standard for lung cancer staging. The new needles will expand the line of devices from Olympus, offering improved access, usability and puncture of difficult-to-access lymph node targets.

Center Valley, PA (May 18, 2017) - Olympus, a global technology leader in designing and delivering innovative solutions for medical and surgical procedures, among other core businesses, announced today the availability of the new ViziShot 2 single use aspiration needles, expanding the device portfolio for Endobronchial Ultrasound Transbronchial Needle Aspiration (EBUS-TBNA), a minimally invasive alternative to a surgical procedure and considered the gold standard for lung cancer staging. The new needles, to be unveiled at the American Thoracic Society (ATS) Annual conference, will expand the line of devices from Olympus, offering improved access, usability and puncture of difficult-to-access lymph node targets.

For pulmonologists performing EBUS-TBNA, the ViziShot 2 generation of needles offers enhanced precision through benefits that include:

  • Improved access through enhanced flexibility: The advanced needle helps to support access to lymph node targets, which can be difficult to reach with conventional EBUS-TBNA needles.
  • Improved puncture via the sharper needle: The "backcut" design of the ViziShot 2 provides a sharper needle, reducing puncture force required to sample even calcified lymph nodes.
  • Enhanced usability with an ergonomic handle and redesigned colored sheath: The ergonomic handle design and improved bronchoscope adapter enable stability and precise puncture control throughout the procedure. The newly designed green-colored sheath provides excellent endoscopic visibility to ensure the needle can be deployed at the exact required location, with minimal sheath movement.
  • Two sizes: Either 21 G or 22 G is available to suit physician needs.

In addition to the ViziShot 2, Olympus will demonstrate its continued commitment to pioneering in the EBUS-TBNA field by introducing the ViziShot 2 FLEX 19 G needle, that features a brand new ergonomic handle. When used with the Olympus BF-UC180F 2.2mm channel EBUS bronchoscope , it provides up to 84 degrees of angulation to help physicians gain access to the most difficult lymph node stations, such as 4L, with ease. This needle has the largest inner lumen currently available in the United States, ensuring improved sample acquisition for advanced molecular testing and enabling physicians to obtain ample quantities of the high-quality specimens needed for a comprehensive histological analysis, especially when diagnosing sarcoidosis and lymphomas.

"Great strides have been made in diagnosing and staging lung cancer and other diseases of the lung using minimally-invasive approaches, and we are proud of our contributions," said Kurt Heine, Group Vice President of the Endoscopy Division at Olympus America Inc. "Our continued commitment to pulmonologists to advance minimally-invasive methods is driven by the evidence that such approaches improve patient outcomes, cost containment and patient satisfaction."

Lung cancer is the leading cause of cancer-related deaths in the U.S., according to the Centers for Disease Control, with more than 400 Americans each day dying from the disease. Early diagnosis and accurate staging of lung cancer can lead to improved treatment. Other diseases are also better managed via EBUS-TBNA.

In July 2013, The U.S. Preventive Services Task Force (USPSTF) announced new recommendations for lung cancer screening for people at high risk for lung cancer, leading to increases in CT screening. Around the same time, the American College of Chest Physicians changed its lung cancer guidelines, now recommending Endobronchial Ultrasound over surgery for lung cancer staging. Many of these patients require follow-up care that could, by USPSTF estimates, prevent roughly 14% of the 160,000 lung cancer deaths each year. Recent CMS increases in reimbursement for procedures related to lung cancer diagnosis allow hospitals to more readily build their lung cancer program.

The new EBUS needles will be showcased at the ATS annual conference May 19-24 in Washington, D.C., booth # 923. To learn more about pulmonary therapeutic devices from Olympus, please call 1-800-387-0437 or visit us at http://medical.olympuscanada.com.

# # #

About Olympus Medical Systems Group
Olympus Medical Systems Group, a division of global technology leader Olympus, develops solutions for healthcare professionals that help improve clinical outcomes, reduce overall costs and enhance quality of life for their patients. By enabling less invasive procedures, innovative diagnostic and therapeutic endoscopy, and early stage lung cancer evaluation and treatments, Olympus is transforming the future of healthcare. For more information visit Olympus at http://medical.olympuscanada.com.